W1203425 - 7.328.125
Série: Smart MULTIVERT® i-Xtensio
Interrupteur-sectionneur à fusible NH MULTIVERT® Taille 3 630A 3x1 pôle/coupure Système bus bar 185mm Borne V E.on Smart
MERSEN Smart monitoring solution is key to answer to new challenges of the electrical power grid! The development of smart Low voltage grids will enable better understanding of the behavior of local LV networks in the context of decentralization and volatility of renewable power sources and of EV charging stations, among others. Instant monitoring of the network values and status allows a more efficient load & demand management and higher network availability. Critical or heavily loaded network sections can then be specifically monitored to perform preventive maintenance and high service continuity. The most user-friendly and most compatible smart monitoring module for NH vertical fuse switch disconnectors ! The compact module designed by Mersen is by far the simplest to install monitoring device and adapts perfectly to the Multivert i-Xtensio ranges that are available today. The product has been engineered to be fully compatible with Energy Monitoring systems existing on the market and has a very compact design for tremendous functionalities. This device makes the data available for the end-user that can connect directly on the Modbus modules. The modules measures relevant data directly on the fuse switch disconnector and enables the users to access instantaneously to main data of energy consumption.
Interrupteur-sectionneur à fusible NH MULTIVERT® Taille 3 630A 3x1 pôle/coupure Système bus bar 185mm Borne V E.on Smart
MERSEN Smart monitoring solution is key to answer to new challenges of the electrical power grid! The development of smart Low voltage grids will enable better understanding of the behavior of local LV networks in the context of decentralization and volatility of renewable power sources and of EV charging stations, among others. Instant monitoring of the network values and status allows a more efficient load & demand management and higher network availability. Critical or heavily loaded network sections can then be specifically monitored to perform preventive maintenance and high service continuity. The most user-friendly and most compatible smart monitoring module for NH vertical fuse switch disconnectors ! The compact module designed by Mersen is by far the simplest to install monitoring device and adapts perfectly to the Multivert i-Xtensio ranges that are available today. The product has been engineered to be fully compatible with Energy Monitoring systems existing on the market and has a very compact design for tremendous functionalities. This device makes the data available for the end-user that can connect directly on the Modbus modules. The modules measures relevant data directly on the fuse switch disconnector and enables the users to access instantaneously to main data of energy consumption.
Fiche produits
pdf - 1.2 Mo
Compliances
pdf - 327.02 Ko
pdf - 327.04 Ko
pdf - 212.67 Ko
pdf - 266.91 Ko
Numéro d'article | W1203425 |
Numéro de catalogue | 7.328.125 |
Description | Interrupteur-sectionneur à fusible NH MULTIVERT® Taille 3 630A 3x1 pôle/coupure Système bus bar 185mm Borne V E.on Smart |
Code EAN / UPC | 3605340705096 |
Fréquence (Hz) | 50 ... 60 Hz |
Catégorie d'utilisation | AC 23 B @ Ue = AC 400 V; Ie = 630 A AC 22 B @ Ue = AC 500 V; Ie = 630 A AC 21 B @ Ue = AC 690 V; Ie = 630 A |
Commutabilité | 3x1-pole switching |
Conforme à ROHS | Oui |
Taille du fusible | 3 |
Détails de conception | MULTIVERT® 7.328.025 with V-terminals, pre-cabled with 3x CTs 600/1A, 5 VA, class 1, 3-Phase voltage measurements and Smart module SM-RTU/1. Fully compliant to E.on Specification |
Nombre de pôles | 3-Pole |
Degré de pollution | 3 |
Tension nominale de tenue aux impulsions | 12 kV |
Tension d'isolation nominale | 1000 V |
Tenue au court-circuit nominal | 12.6 kA / 1 s |
Dissipation maximale des parties fusibles Pn | 48 W |
Dissipation maximale des parties solides Pn | 17.5 W |
Power Dissipation by Ith without Fuse-Links | 95 W |
Capacité nominale de court-circuit avec les parties solides Icm | 16 kA |
Installation de montage | Système bus bar 185 mm |
Largeur du produit | 98 mm |
Longueur du produit | 223 mm |
Hauteur du produit | 725 mm |
Quantité du pack de vente | 1 EA |
Poids du pack de vente | 7.5 kg |
Largeur du pack de vente | 130 mm |
Longueur du pack de vente | 240 mm |
Hauteur du pack de vente | 810 mm |
Groupe de produits | Interrupteurs sectionneurs Fusibles IEC |
Poids du produit | 6.3 kg |
Conventional Free Air thermal Current With Fuse-Links Ith | 630 A |
Courant thermique conventionnel à l'air libre - Parties solides | 800 A |