Fusible EVpack MEV55, 550 VDC maxi., L/R - 1 ms, 5 - 50 A
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Fiche produits
Brochures et Flyers
- BR-Fuses-and-Overcurrent-Protection-Devices-Brochure
pdf - 13.74 Mo
- Mersen-Solutions-for-EV-HEV-e-Mobility-EN
pdf - 5.21 Mo
Applications produits
- AN-E-Mobility-Overcurrent-Protection-Guide-Mersen
pdf - 851.11 Ko
Compliance
- COM-RoHS-RS000117-MEV55-Mersen
pdf - 142.27 Ko
- COM-REACH-RE000117-MEV55-Mersen
pdf - 284.29 Ko
- COM-CE-CE0002-MEV55C-MEV70V-Mersen
pdf - 183.16 Ko
Caractéristiques et avantages
Design for DC applications
Low watt losses
High cycling performance
Full coverage of battery module voltage and current
Ultra compact size
Current Ratings (In): 5 to 800A
Interrupting Rating (IR) for MEV55C: 20kA @550VDC, L/R ≤ 1ms
Interrupting Rating (IR) for MEV50A: 30kA @500VDC, L/R ≤ 2.5ms
Applications
EV/HEV
Battery pack protection
Battery Disconnect Unit (BDU)
Battery Management Systm (BMS)
Battery Junction Box for auxiliaries
On-Board Charging
Amperage Range | 5…50 A |
Conformité CE | Oui |
Conforme à REACH | Oui |
Les références de cette gamme
Scroll
Numéro d'article | Courant assigné | Taille du fusible | I2t total de coupure à tension nominale | Système d'indication | Poids du produit |
---|---|---|---|---|---|
MEV55C20-P - MEV55C20-P Voir le produit
|
20A | - | - | Non | 0.0099kg |
MEV55C20-S - MEV55C20-S Voir le produit
|
20A | - | - | Non | 0.0099kg |
MEV55C25 - MEV55C25 Voir le produit
|
25A | - | - | Non | 0.0075kg |
MEV55C25-P - MEV55C25-P Voir le produit
|
25A | - | - | Non | 0.0099kg |
MEV55C25-S - MEV55C25-S Voir le produit
|
25A | - | - | Non | 0.0099kg |
MEV55C30 - MEV55C30 Voir le produit
|
30A | - | - | Non | 0.0075kg |
MEV55C30-P - MEV55C30-P Voir le produit
|
30A | - | - | Non | 0.0099kg |
MEV55C30-S - MEV55C30-S Voir le produit
|
30A | - | - | Non | 0.0099kg |
MEV55C30/40 - MEV55C30/40 Voir le produit
|
40A | - | - | Non | 0.0075kg |
MEV55C30/40-S - MEV55C30/40-S Voir le produit
|
40A | - | - | Non | 0.0099kg |