Précédent
PHP-DCBPMEV100-MSL

Fusible EVpack MEV100A, 1000 VDC maxi., L/R - 1 ms, 8 - 300 A, fusible cylindrique

Normes
Complies to Automotive IATF 16949:2016 Quality System
Power Cycling & Vibration JASO D622

EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.

EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.

Caractéristiques et avantages

  • Design for DC applications

  • Low watt losses

  • High cycling performance

  • Full coverage of battery module voltage and current

  • Ultra compact size

  • Current Ratings (In): 8 to 300A

  • Interrupting Rating (IR): 20kA @ 1,000 VDC, L/R ≤1ms

  • Self Certified IR = 100kA, 1000VDC, L/R ≤ 3.7ms (UL Recognition Pending)

Applications

  • EV/HEV

  • Battery pack protection

  • Battery Disconnect Unit (BDU)

  • Battery Management System (BMS)

  • Battery Junction Box for auxiliaries

  • On-board charger

Caractéristiques produit
Amperage Range 50…200 A
Conformité CE Oui
Conforme à REACH Oui
Température maximale de fonctionnement 125 °C
Température de fonctionnement minimale -40 °C

Les références de cette gamme

Numéro d'article Courant assigné Taille du fusible I2t total de coupure à tension nominale Système d'indication Poids du produit
MEV100A225-4 - MEV100A225-4 Voir le produit
225A - - Non 0.301kg
MEV100A250-4 - MEV100A250-4 Voir le produit
250A - - Non 0.301kg
MEV100A300-4 - MEV100A300-4 Voir le produit
300A - - Non 0.301kg
MEV100A50-4 - MEV100A50-4 Voir le produit
50A - - Non 0.117kg
MEV100A50-4Y - MEV100A50-4Y Voir le produit
50A - - Non 0.12kg
MEV100A60-4 - MEV100A60-4 Voir le produit
60A - - Non 0.117kg
MEV100A60-4Y - MEV100A60-4Y Voir le produit
60A - - Non 0.12kg
MEV100A70-4 - MEV100A70-4 Voir le produit
70A - - Non 0.117kg
MEV100A70-4Y - MEV100A70-4Y Voir le produit
70A - - Non 0.12kg
MEV100A80-4 - MEV100A80-4 Voir le produit
80A - - Non 0.117kg
Back to top