MEV100A175-4Y - MEV100A175-4Y
EVpack 1000VDC UL 175A Pouvoir de coupure max. DC: 20 kA @ 1000 V L/R ≤ 1 ms Boulonné M8
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.
EVpack 1000VDC UL 175A Pouvoir de coupure max. DC: 20 kA @ 1000 V L/R ≤ 1 ms Boulonné M8
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.
Fiche produits
pdf - 763.17 Ko
Compliances
pdf - 280.24 Ko
pdf - 215.15 Ko
pdf - 215.15 Ko
Numéro d'article | MEV100A175-4Y |
Numéro de catalogue | MEV100A175-4Y |
Description | EVpack 1000VDC UL 175A Pouvoir de coupure max. DC: 20 kA @ 1000 V L/R ≤ 1 ms Boulonné M8 |
Code EAN / UPC | 0782001491529 |
Tension nominale DC UL | 1000 V |
Courant assigné | 175 A |
Conforme à ROHS | Oui |
AC ou DC | DC |
Montage | Boulonné |
Pouvoir de coupure minimal (MBC) | 1320 A |
Max. Rated Breaking Capacity DC | 20 kA @ 1000 V, L/R ≤ 1 ms |
Connexion / Matériel terminal | Laiton étamé |
Type de Connexion / Borne | Boulonné |
Diamètre du produit | 31 mm |
Longueur du produit | 111 mm |
Quantité du pack de vente | 5 EA |
Poids du pack de vente | 0.95 kg |
Largeur du pack de vente | 147 mm |
Longueur du pack de vente | 205 mm |
Hauteur du pack de vente | 39 mm |
Groupe de produits | EV and Battery Protection Fuses |
Poids du produit | 0.19 kg |
Dissipation thermique à la valeur de courant intermédiaire | 6.3 W @ 0.5 In |