EVpack-fuse MEV50, 500 VDC Max., L/R less than or equal 2.5ms, 60 - 800A
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Fiche produits
Brochures et Flyers
- Mersen-Solutions-for-EV-HEV-e-Mobility-EN
pdf - 5.21 Mo
Compliance
- COM-CE-ROHS-declaration-CN0002-MEV50A
pdf - 157.17 Ko
- COM-REACH-declaration-CN0002-MEV50A
pdf - 194.54 Ko
- COM-UKCA-declaration-CN0002-MEV50A
pdf - 157.1 Ko
Caractéristiques et avantages
Design for DC applications
Low watt losses
High cycling performance
Full coverage of battery module voltage and current
Ultra compact size
Current Ratings (In): 5 to 800A
Interrupting Rating (IR) for MEV55C: 20kA @550VDC, L/R ≤ 1ms
Interrupting Rating (IR) for MEV50A: 30kA @500VDC, L/R ≤ 2.5ms
Applications
EV/HEV
Battery pack protection
Battery Disconnect Unit (BDU)
Battery Management Systm (BMS)
Battery Junction Box for auxiliaries
On-Board Charging
Amperage Range | 60…800 A |
Vitesse/Caractéristique | aR |
Conformité CE | Oui |
Conforme à REACH | Oui |
Les références de cette gamme
Scroll
Numéro d'article | Courant assigné | Taille du fusible | I2t total de coupure à tension nominale | Système d'indication | Poids du produit |
---|---|---|---|---|---|
MEV50A100-20G - MEV50A100-20G Voir le produit
|
100A | 20G | - | Non | 0.041kg |
MEV50A100-25G - MEV50A100-25G Voir le produit
|
100A | 25G | - | Non | 0.075kg |
MEV50A125-20G - MEV50A125-20G Voir le produit
|
125A | 20G | - | Non | 0.041kg |
MEV50A125-25G - MEV50A125-25G Voir le produit
|
125A | 25G | - | Non | 0.075kg |
MEV50A150-20G - MEV50A150-20G Voir le produit
|
150A | 20G | - | Non | 0.041kg |
MEV50A150-25G - MEV50A150-25G Voir le produit
|
150A | 25G | - | Non | 0.075kg |
MEV50A150-30G - MEV50A150-30G Voir le produit
|
150A | 30G | - | Non | 0.1kg |
MEV50A200-25G - MEV50A200-25G Voir le produit
|
200A | 25G | - | Non | 0.075kg |
MEV50A200-30G - MEV50A200-30G Voir le produit
|
200A | 30G | - | Non | 0.1kg |
MEV50A250-25G - MEV50A250-25G Voir le produit
|
250A | 25G | - | Non | 0.075kg |